title: "Available mounting kits"
canonical: "https://farmconnect.docs.rubiconwater.com/space/BY/2323546133/Available%20mounting%20kits"
format: markdown
---
> Macro (toc)

> ℹ️ **Note**
> ℹ️ 
> ℹ️ - The BayDrive model should be selected according to the sizing chart.
> ℹ️ - The top beam dimensions should be selected according to the bay structure dimensions.

## 82348: Mounted directly to the concrete top of the outlet structure

**Model**: Standard

**Top beam dimensions:** N/A

**Mounting kit**: 82348

**Description**:

Kit to mount the BayDrive direct to the concrete top of a bay outlet structure. This option is for the new design BayDrive cast base only.

## 82328: Short top beam dynabolted to the concrete top of the outlet structure

**Model**: Standard

**Top beam dimensions:** Length: 610, Depth: 50, Width: 150

**Mounting kit**: 82328

**Description**:

Short top beam dynabolted directly to the concrete top of a bay outlet structure. This enables transition from the old design BayDrive cast base where bolt holes are too far apart to dynabolt directly to concrete (due to insufficient edge distance). You can optionally add extra height to a BayDrive installation if extra closing distance is required.

## 82329: Top beam mounted to an existing winch actuation steel bar

**Model**: Standard

**Top beam dimensions:** Length: 1520, Depth: 50, Width: 150

**Mounting kit**: 82329

**Description**:

This kit is to mount a top beam to the existing winch actuation galvanised steel bar that sits to the upstream side of the structure. Brackets are clamped to the bar.

## 82326: Brackets dynabolted to the structure wings

**Model**: Standard

**Top beam dimensions:** Length: 1520 Depth: 50 Width: 150

**Mounting kit**: 82326

**Description**:

Brackets dynabolted to the structure wings where the top beam can be installed to the upstream side of the Gate pivot point (if the Gate needs to close to a vertical position). Ideally the structure wings should be square (or close to) and at least 70mm edge distance from anchor bolts.

## 82327: Brackets dynabolted to the structure wings 

**Model**: Standard

**Top beam dimensions:** Length: 2100, Depth: 50, Width: 150

**Mounting kit**: 82327

**Description**:

Brackets dynabolted to the structure wings where the top beam can be installed to the upstream side of the Gate pivot point (if the Gate needs to close to a vertical position). Ideally the structure wings should be square (or close to) and at least 70mm edge distance from the anchor bolts.

## 83587: Brackets dynabolted to the structure wings 

**Model**: Deep

**Top beam dimensions:** Length: 1520, Depth: 76, Width: 152

**Mounting kit**: 83587

**Description**:

Brackets dynabolted to the structure wings where the top beam can be installed to the upstream side of the Gate pivot point (if the Gate needs to close to a vertical position). Ideally the structure wings should be square (or close to) and at least 70mm edge distance from the anchor bolts.

## 82331: Brackets dynabolted to the structure wings

**Model**: Deep

**Top beam dimensions:** Length: 3200, Depth: 76, Width: 152

**Mounting kit**: 82331

**Description**: 

Brackets dynabolted to the structure wings where the top beam can be installed to the upstream side of the Gate pivot point (if the Gate needs to close to a vertical position). Ideally the structure wings should be square (or close to) and at least 70mm edge distance from the anchor bolts.

## 84436: Brackets dynabolted to the structure wings

**Model**: Deep

**Top beam dimensions:** Length: 2200, Depth: 76

**Mounting kit**: 84426

**Description**:

Brackets dynabolted to the structure wings where the top beam can be installed to the upstream side of the Gate pivot point (if the Gate needs to close to a vertical position). Ideally the structure wings should be square (or close to) and at least 70mm edge distance from the anchor bolts.

## 82332: Brackets on extensions dynabolted to the structure wings

**Model**: Deep

**Top beam dimensions:** Length: 1850, Depth: 76, Width: 152

**Mounting kit**: 82332

**Description**:

This kit uses ‘outriggers’ dynabolted to the structure wings with brackets fastened to the ‘outriggers’. Used where the top beam needs be installed upstream of the structure to ensure actuation is upstream of the Gate pivot point (if the Gate needs to close to vertical position). Ideally the structure wings should be square (or close to) and at least 70mm edge distance from anchor bolts.

## 83750: Mounted vertically to the inside face of the structure wings,

**Mounting kit**: 83750 (additional) 

**Description**:

Mounts vertically to the inside face of the structure wings. The brackets fasten to this. Used where the edge distance would be less than 70mm. 

> ℹ️ **Note**
> ℹ️ 
> ℹ️ Works with 83587/82326/82327

---