title: "Commission a MicronLevel Air Sensor"
canonical: "https://farmconnect.docs.rubiconwater.com/space/BY/2330066977/Commission%20a%20MicronLevel%20Air%20Sensor"
format: markdown
---
> ℹ️ **Note**
> ℹ️ 
> ℹ️ The settings and data units depend on your browser language. Ensure that you have selected English (Australia) to display as metric, or English (United States) to display as Imperial.

**Step 1**

[Reconnect to the FerIT Solar Node](https://rubiconwater.atlassian.net/wiki/spaces/BY/pages/1961164896/Commissioning+and+Configuration#Connect-to-the-FerIT-SolarNode) and [open the Micron Level driver](https://rubiconwater.atlassian.net/wiki/spaces/DC/pages/1914896447/Viewing+and+Managing+Devices#View-and-Modify-Driver-Settings-and-Data) from the **Drivers** tab. Then select the **Diagnostic** tab.

**Step 2**

Confirm that the FerIT Solar Node is communicating with the sensor by checking the **Comms Status** field

**Step 3**

Configure the ‘Device Datum’: With a tape measure, measure down from the face of the level sensor to the ground.  Enter this value in the **Device Datum** field so that the displayed measurement value is in reference to the ground.

**Video: Calibrating Water Level to Ground**

> Macro (excerpt)
> 
> ![RUB_Tutorial_FC-DeviceConnect Calibrate Water Level to Ground.mp4](media://04875f34-14c3-41b8-bc48-a8243525ec42)

<details>
<summary>Calibrating Water Level to Ground</summary>

![RUB_Tutorial_FC-DeviceConnect Calibrate Water Level to Ground.mp4](media://04875f34-14c3-41b8-bc48-a8243525ec42)
</details>

**Step 4**

Go to the **Settings** tab.

Configure ‘Change of State’ bursting: If **CoS Bursting** is set to ENABLED, any change in measurement greater than the **CoS Value** will trigger a burst of data back to the host system.  This is recommended if using the level sensor for [https://rubiconwater.atlassian.net/wiki/spaces/FCD/pages/2029586433](https://rubiconwater.atlassian.net/wiki/spaces/FCD/pages/2029586433).

**Step 5**

Configure ‘Percentage Full’ parameters: if measurement of the water level as a percentage of full is required, configure the **Custom Range Minimum **by entering the measurement equivalent to 0% full and configure the **Custom Range Maximum** by entering the measurement equivalent to 100% full.  The percentage full will be calculated in this measurement range.

**Video: Configure Water Level % Full Feature**

<details>
<summary>Configure Water Level % Full Feature</summary>

![image](media://5e14b7bb-121a-4059-9d7e-074021d6ae68)
</details>

> Macro (excerpt)
> 
> ![image](media://5e14b7bb-121a-4059-9d7e-074021d6ae68)

The MicronLevel Air Sensor is now fully commissioned and configured. 

---