title: "Civil Modifications for Framed Door Kit"
canonical: "https://farmconnect.docs.rubiconwater.com/space/BY/2484338725/Civil%20Modifications%20for%20Framed%20Door%20Kit"
format: markdown
---
> Macro (toc)

This section summarises the potential civil modifications that may be required to retro-fit a framed door kit to an existing door installation.

> ℹ️ **Note**
> ℹ️ 
> ℹ️ Select a door kit to suit the culvert shape and size. See the [82280 DD BayDrive Sales Drawing](https://bit.ly/3qoPvKg) for available options.
> ℹ️ 
> ℹ️ The framed door kit comes in the following configuration:
> ℹ️ 
> ℹ️ - Direct bay outlet (P/N 83901, 90° opening).

## Direct Bay Outlet (83901)

***Prior to installation***, ensure that:

1. There is sufficient clearance downstream of the existing frame to
  1. fit the frame exterior of the framed door kit (925mm / 36.5” horizontal distance between existing frame and pipe headwall, 1145mm / 45” width)
  2. provide clearance for the door to fully open (1145mm / 45” width along full travel of door)
2. The existing frame dimensions are
  1. 914mm / 36” height minimum
  2. 1143mm / 45” width

---