title: "Pronamic Tipping Bucket Rain Gauge"
canonical: "https://farmconnect.docs.rubiconwater.com/space/FCKB/2324791356/Pronamic%20Tipping%20Bucket%20Rain%20Gauge"
format: markdown
---
See the [Pronamic website](https://pronamic.com/) for more information about the Pronamic tipping bucket rain gauge.

> Macro (toc)

# Requirements

| **Description** | **Rubicon Part Number** | **Notes** |
| --- | --- | --- |
| Pronamic Tipping Bucket Rain Gauge | 79785 | Pronamic Professional Rain Gauge item no 300.023-20 |
| Mounting Bracket | Contact Rubicon for options |  |
| FerIT Solar Node | [81840 DD FerIT Solar Node Dimensional Data and Selection](https://bit.ly/3fmn753) |  |
| Open Collector Loom | 81897 | 520mm length |
| Bluetooth-enabled Device | - | Refer to [https://rubiconwater.atlassian.net/wiki/spaces/DC](https://rubiconwater.atlassian.net/wiki/spaces/DC) |

# Setup

> ⚠️ Please make safety a priority when you are carrying out any work at a site. We recommend that you perform a site-specific risk assessment to identify any potential risks before commencing any work at a site.
> ⚠️ 
> ⚠️ See the [https://rubiconwater.atlassian.net/wiki/spaces/GM/pages/1925186045](https://rubiconwater.atlassian.net/wiki/spaces/GM/pages/1925186045) section for more information about specific risks and recommended procedures. Specific safety information is also provided in relevant topics.

## Installing the FerIT Node

Refer to the [https://rubiconwater.atlassian.net/wiki/spaces/FER](https://rubiconwater.atlassian.net/wiki/spaces/FER) documentation  for installation instructions

## Connecting the Rain Gauge

Thread the 81897 loom through the mounting bracket to the circuit board and connect to the screw terminals as below

| **Rain Gauge PCBA No** | **81897 Wire** | **Rain Gauge PCBA Terminal** |
| --- | --- | --- |
| 9602 - Normally Open (standard) | Positive (White and Grey) | 3 |
|  | Negative (Green) | 4 |
| 9601 - Normally Closed | Positive (White and Grey) | 1 |
|  | Negative (Green) | 2 |

## Driver Installation

> ℹ️ Refer to the [https://rubiconwater.atlassian.net/wiki/spaces/DC](https://rubiconwater.atlassian.net/wiki/spaces/DC) documentation for procedures to install and configure drivers

Pronamic tipping bucket uses the ‘Rain Gauge Pulse' driver in the FerIT device

The default driver configuration assumes **Normally Open (N.O.)** configuration (**9602**) with a **4ml Spoon**, which is the typical hardware supplied by Rubicon.  Check if your device is configured in this way. 

1. Connect the battery
2. In DeviceConnect, scan for devices. Once found, connect the the FerIT
3. Navigate to the **Drivers** tab and select **Add**, then find and add the 'Rain Gauge Pulse' driver.
4. Enter the access code provided
5. Allow the FerIT to restart and then reconnect

## Driver Configuration

> ⚠️ The settings and data units are dependant on your browser language. Ensure you have selected English (Australia) to display as metric, or English (United States) to display as Imperial

> ⚠️ Driver operation requires FerIT to have an active LoRa connection to the network, in order to get a valid time sync for periodic calculations to occur.

1. In the Driver tab, select the Rain Gauge Pulse driver and navigate to the **Settings **tab
2. Apply the settings based on your rain gauge option, adjusting based on the ‘Settings Description’ table below
3. Once configured, reset the FerIT via DeviceConnect. Allow the FerIT to restart and then reconnect
4. In the Driver tab, select the Rain Gauge Pulse driver and navigate to the **Data **tab
5. Confirm that the pulse gauge is operating as expected by manually triggering a bucket tip, and observing that the VOLUME increases by the correct amount

### Settings Descriptions

|  |  |
| --- | --- |
| **Property** | **Description** |
| Pulse Width (min, max)<br>Pulse Polarity<br>Pulse V Ref | The default configuration will work for a **100-500ms**, **active low**, pulse that is idle (pulled-up) to **12V**.<br>9602 N.O., with 4ml spoon. Adjust accordingly for other configurations |
| mm Per Pulse | Adjust this to match the spoon size of the tipping bucket<br>Default** 0.2mm / 4ml spoon** |
| Rainfall Time Resolution | Resolution for rainfall volume timeseries data. Each slot holds n minutes of rainfall  
Default **5 minutes**. |
| Rainfall Update Hour | Hour of the day in 24-hour time at which the variable ACCUMULATED DAILY RAINFALL is cleared<br>Default **9AM** |
| Burst Period | Set this to the desired bursting/transmit period. |

### Data Variable Descriptions

All volume values are updated at either the time of last burst, or whenever there is a bucket tip

|  |  |
| --- | --- |
| **Property** | **Description** |
| 15min Rainfall Volume | Rainfall in the last 15 minutes |
| Hourly Rainfall Volume | Rainfall in the last hour |
| Daily Rainfall Volume | Rainfall since the time set in Rainfall Update Hour |
| Periodic Rainfall Volume | Rainfall since the last burst |

### Inspection Test Plan (ITP):

Download and complete the ITP

[0080-ITP-FerIT Node Monitoring Device (LoRa) Commission.pdf](https://bit.ly/3aUO8Ov)

## Accessing your Data through FarmConnect

See [https://rubiconwater.atlassian.net/wiki/spaces/FCD/pages/2022342685](https://rubiconwater.atlassian.net/wiki/spaces/FCD/pages/2022342685) for general information on accessing device data through the FarmConnect Portal.

![image-20240731-011221.png](media://4c358d4e-4c32-4bd5-99dc-1c93d879cf8a)

*Example Rain Gauge Overview screen*